Part
No
|
DC
Breakdown
Voltage
(V)
|
Maximum
Impulse
Breakdown
Voltage
(V)
|
Maximum
Impulse
Discharge
Current
(8/20 µs)
(KA)
|
Impulse
Life
(10/1000µs)(100A)
|
DC
Holdover
Voltage
(V)
|
Minimum
Insulation
Resistance
(GW)
|
Maximum
Capacitance
(pf)
|
100V/s
|
100V/µs
|
1000V/µs
|
1 time
|
10 times
|
times
|
<150ms
|
Note2
|
1MHZ
|
LSE-071LX 2P
|
70 ±15%
|
500
|
600
|
15
|
10
|
500
|
52
|
1
|
1.5
|
LSE-075LX 2P
|
75 ±15%
|
500
|
600
|
52
|
1
|
1.5
|
LSE-091LX 2P
|
90 ±15%
|
500
|
600
|
52
|
1
|
1.5
|
LSE-121LX 2P
|
120 ±15%
|
500
|
700
|
52
|
1
|
1.5
|
LSE-131LX 2P
|
130 ±15%
|
500
|
700
|
52
|
1
|
1.5
|
LSE-145LX 2P
|
145 ±15%
|
500
|
700
|
52
|
1
|
1.5
|
LSE-231LX 2P
|
230 ±15%
|
500
|
700
|
80
|
1
|
1.5
|
LSE-251LX 2P
|
250 ±15%
|
500
|
700
|
135
|
1
|
1.5
|
LSE-301LX 2P
|
300 ±15%
|
700
|
900
|
150
|
1
|
1.5
|
LSE-351LX 2P
|
350 ±15%
|
700
|
900
|
150
|
1
|
1.5
|
LSE-401LX 2P
|
400 ±15%
|
800
|
1000
|
150
|
1
|
1.5
|
LSE-471LX 2P
|
470 ±15%
|
900
|
1100
|
150
|
1
|
1.5
|
LSE-601LX 2P
|
600 ±15%
|
1100
|
1300
|
10
|
5
|
500
|
150
|
1
|
1.5
|
LSE-801LX 2P
|
800 ±15%
|
1300
|
1500
|
150
|
1
|
1.5
|
Dimensions: (Unit: mm)
Item
|
Dimensions
|
D
|
8.0 + 0.3,-0.5
|
T
|
6.0 + 0.3,-0.5
|
d
|
0.8 or 1.0 ± 0.05
|
L
|
20min.
|
 |